The air degenerator made by Pars Keyld Taban Company is a stainless steel product insulated with sulfur hexafluoride gas and designed, manufactured and tested specifically for installation in the open environment outside. The design of this product is unique, without the need to go outside the borders of the country, entirely by creative, capable and young Iranian engineers, in a laboratory environment. It prevents the supply to the market and the exit of currency, for its own share.
Below are some of the advantages of the above equipment:
1. Due to the location of the two spring mechanism in the above equipment and the reduction of the circuit interruption time to below 70 milliseconds, it gives the user the possibility to control the circuit through the protective relay and in case of an error, the circuit is closed in the minimum time to prevent Cut the main lines.
2. According to the description of item number 1, this equipment can be used to protect equipment such as MOF, power transformers and network sub-lines due to its suitable capability and lower cost.
3. As mentioned, this product has been insulated, tested and safety controlled in the factory by SF6 gas before being sent to the consumer; Pre-shipment inspection means that the quality control experts of Pars Kilid Taban Company, after ensuring the proper pressure of the gas and its non-leakage, apply strict tests in accordance with international standards, and if the results are approved, they are allowed to leave the The factory is exported; This set of tests and controls
performed on the product, gives the consumer the assurance that due to the sensitivity of the air degenerator, this product will not suffer from technical defects during its useful life.
Safety notice!
It is necessary to take the following things into consideration during installation and commissioning in order to increase the lifespan of the equipment:
1. When transporting or checking the product, avoid hitting the bushings, connection points, etc. During the delivery of the product, if any abnormal dent, deformation, etc. is observed in the product, immediately contact the after-sales service unit of Pars Kilid Taban Company and refrain from using it until the result is determined.
2. In order to coordinate the protection of the equipment with the relays of the sub-distribution substation, only the currents connecting the phase to the ground should be checked by the protection relay and then the order to disconnect the degenerator should be issued. Therefore, when programming the protective relay, the short circuit current item must be set to Disable.
3. The distance between the installation location of the equipment and the above substation at voltage levels of 11 and 20 kV should be more than 13 and 20 km, respectively.
4. It is suggested to use cut-out fuse blades to protect the short circuit at the entrance of the equipment