Ground gas disconnectors are one of the most widely used technologies in electrical circuit breakers in the power distribution network, and in this equipment, sulfur hexafluoride gas (SF6) is used to turn off the INTERNAL ARC that occurs during switching, also considering Using gas insulation instead of other insulating materials, the dimensional volume of the equipment has also been reduced and compacted. These sectionalizers are produced and used in two types: load break switch or disconnector switch. becomes (Additional details on the product page)
In order to achieve goals such as optimal and comprehensive management of electrical energy distribution systems, definitive reduction of electricity flow and control of the distribution network, smart switches with modern technology are needed. Therefore, a well-defined system should be created for today's electricity industry users. These sectioners are also called gas sectioners that can be cut off under load, which have two types, aerial and ground. Gas air sectioners are designed with SF6 gas insulation of good quality, high efficiency and excellent reliability. This sectioner can be used and operated in all medium pressure distribution networks (20 kV) and maneuver in disconnecting and connecting distribution networks with a disconnection power of 630 amps. (Additional details on the product page)
This type of key does not use a spark to open and close the contacts, and in general, keys with a vacuum mechanism have a different structure from other keys, one of the important features of the mentioned keys is sealing and not being exposed to pollution in industrial environments. Long service life without the need for supply and maintenance, negligible noise during maneuvering. Vacuum degenerators have the ability to interrupt high-intensity short-circuit currents. (Additional details on the product page)
This device, which is also known as a circuit breaker, is a type of protective device. This circuit breaker also has the ability to cut off the load. The main function of this device is to protect circuit equipment against short circuit or overload. In fact, it opens and closes the circuit in the normal state and the faulty state of the system.
The degenerator switch is disconnected or connected both manually (control room) and automatically under certain conditions that we will mention. This switch is used in the circuit of high voltage switchboards. For this reason, the existence of items such as electric arc, protection and insulation are of great importance. In fact, the use of degenerators prevents further damage to electrical equipment
A recloser is a small circuit breaker that is usually located at the top of a power distribution pole and is typically used in very long distribution feeders. The task of the reclosers is to isolate a part of the feeder in the event of a fault or overload and thus minimize the number of consumers without electricity. Because the recloser relay acts as a small circuit breaker, it has the ability to automatically restore power under temporary fault conditions and is therefore called a recloser. (Additional details on the product page)
A three-way switch or changeover switch is a type of switch that can divide the electric load at a certain current level between two power sources separately or vice versa. Usually, this happens somewhere between two continuous circuits when one of them is out of power. (Additional details on the product page)
RMU panels by using SF6 gas chamber for keys and main busbar have been able to solve most of the problems related to the required space of the substations by observing safety, and at the same time, these panels can be designed and made for outdoor primary substations up to the voltage level of 36KV. is used (Additional details on the product page)